A customer tested a 12V100Ah LiFePO4 battery pack and found it shut down at 10.2V.
According to the spec sheet, with single-cell protection at 2.30V, a 4S pack should cut off at 9.2V. The customer's first reaction: the BMS is defective. Factory inspection: the protection board was perfectly normal.
The real issue was cell consistency. When one cell dropped to 2.30V first, the other three still had 2.9V, 2.8V, and 2.7V—the pack voltage looked like 10.5V, but the BMS had already forced a shutdown based on the lowest single-cell voltage. This "false failure" gets amplified exponentially below -20°C.
Many engineers worship active balancing, thinking 1-2A high current must be better than passive balancing's 50-100mA. But in extreme cold, this logic reverses.